JKW5C Reactive Power Automatic Compensation Controller

✅Precise Reactive Power Compensation Control,Dynamic Response and various control modes
✅Energy Efficiency and Economic Benefits,improves power factor to above 0.95
✅Supports static compensation and dynamic compensation,hybrid compensation
✅Human-Machine Interface,real-time monitor power statu
✅Self-Diagnosis,Automatically detects issues and triggers alarms
✅Smart Protection:overvoltage,undervoltage,overcurrent,and overheating,with event logging for fault analysis

  • Product Introduction

Jinneng electric JKW5C Reactive Power Automatic Compensation Controller is suitable for balanced distribution networks in low-voltage 400V systems.

It automatically regulates reactive power to achieve a preset power factor, improving the utilization efficiency of power transformers, reducing line losses, enhancing voltage quality, minimizing or eliminating penalty fees for reactive power adjustments, and delivering both economic and social benefits.

 

Usage ambient

 

Category Specification
Altitude Not exceed 2500m
Temperature -25°C ~ +40°C
Humidity ≤ 50% at 40°C,  ≤ 90% at 20°C
Ambient No severe vibration at the installation site
Voltage distortion rate < 20%
Rated Voltage Single Phase 230V, Three phase 400V
Rated Frequency 50Hz
Voltage range 90% - 120%
Current range 0-5.5A
Power consumption <3VA
Node Control Capacity 5A/220V/loop
Active Control Capacity -12V/8mA/loop
Switch Control Mode Cyclic switching (equal capacity), Optimal switching (unequal capacity)
Installation Type

recessed instalation

Cut-Size 110mm x 110mm

 

Controller LED Status Indicators

 

LED Indicator Meaning
Pre-engagement Indicates that after a delay, the controller will engage a capacitor.
Pre-disconnection Indicates that after a delay, the controller will disconnect a capacitor.
Overvoltage The sampled voltage exceeds the voltage threshold. The controller will disconnect capacitors sequentially.
Over-distortion The sampled voltage distortion rate exceeds the threshold. The controller will disconnect capacitors sequentially.
Lockout The controller has detected repeated switching. It will stop engaging for 30 minutes or until reactive power exceeds 1.3X of the oscillation threshold.
1-12 Loop Indicates the number of capacitor loops currently engaged (1 to 12).
Auto mode The controller is operating in automatic mode.
Manual mode The controller is in manual mode. Use ▲ to engage or ▼ to disconnect capacitors.
Settings The controller is in parameter adjustment mode. Control settings can be modified.

 

Maintance:

 

The following are common troubleshooting methods of different power device faults.

  • Maintenance and Replacement: For simple faults, devices can be repaired or damaged components replaced to restore normal operation.
  • Technical Analysis: By analyzing root cause, take correct action to improve the device's materials or structure can be verified to enhance reliability and stability.
  • Fault Troubleshooting and Prevention: Regular inspections and maintenance can help promptly identify and address potential faults, preventing recurrence.
  • Professional Operation: The above maintenance and repairs should be conducted by qualified personnel.

 

Product Description

 

Our partners are: State Grid, South grid, Three Gorges China, China National Energy Construction, Tianneng China Nuclear Photovoltaic(CNNC), PetroChina, China Railway, Hong Kong Metro,Siemens, etc.

 