JN-APF 30A ~ 200A series Active harmonic filter AHF can be called as APF(Active power filter) also,it has complete independent intellectual property rights for suppressing power harmonics and dynamic reactive power compensation, specifications including 30A, 50A, 75A, 100A, 150A, 200A.
APF functions: harmonic filter, reactive power compensation, three-phase imbalance compensation, and it can be flexibly configured into a single phase, group mode compensation, it is widely used to improve the power quality of 0.4kV power supply system.
Technical parameter:
|
Item |
Product description |
|
|
Electric parameter |
Capacity (according to the model) |
30A/50A/75A/100A/150A/200A |
|
Input line voltage |
380V ±15% |
|
|
compensation current (per phase) |
30A-150A (according to the model) |
|
|
Compensation range |
2~60 times (configurable) |
|
|
Full response time |
≤10 ms(millisecond) |
|
|
Efficiency |
Up to 98% |
|
|
Dry contact signals |
EPO/DI/DO |
|
|
Communication interface |
Communication protocol |
RS232/RS485/Ethernet/GPRS |
|
Environmental requirement |
Operating temperature |
-45°C ~ +55°C |
|
Structure |
Module weight |
20KG~46KG |
|
Cooling way |
Smart air cooling |
|
Working Principle
APF operates by real-time detection and dynamic compensation of disturbances in the power system:
Step 1: Measures current harmonics/unbalance using FFT (Fast Fourier Transform) or PQ theory.
Step 2: Generates an opposite-phase compensation current using IGBT-based inverters.
Step 3: Injects the compensating current into the grid, canceling out harmonics and reactive power.
contact us
Product dimension:
Two installation methods of the Active harmonic filter AHF: Rack-mounted type, Wall-mounted type

| Installation methods | Rack-mounted | wall-mounted | ||||||||
| Size (mm) | 30A/50A | 75A | 100A | 150A | 200A | 30A/50A | 75A | 100A | 150A | 200A |
| A | 359 | 399 | 484 | 554 | See pic | 521.5 | 545 | 611 | 621 | See pic |
| B | 341 | 381 | 466 | 536 | 500 | 520 | 575 | 585 | ||
| C | 315 | 355 | 440 | 510 | 300 | 360 | 300 | 300 | ||
| D | 200 | 200 | 232 | 250 | 120.5 | 145.5 | 137.5 | 142.5 | ||
| E | 89 | 89 | 89 | 89 | 378 | 419 | 504 | 574 | ||
| F | 55.5 | 55.5 | 71.5 | 80.5 | 350 | 390 | 475 | 545 | ||
| G | 534.5 | 615 | 646 | 656 | 315 | 355 | 440 | 510 | ||
| H | 500 | 555 | 575 | 585 | 200 | 200 | 232 | 250 | ||
| K | 13 | 13 | 35 | 35 | / | / | / | / | ||
Note: Above parameters are typical values for reference only, which can be customized according to customer's requirements, we reserves the right to change the data.
Difference between Rack-mounted type and wall-mounted type:
The differences between rack-mounted and wall-mounted Active Harmonic Filter AHF systems are as follows:
1. Installation Method
Rack-Mounted: Designed to be placed in cabinets or racks, suitable for large-scale power systems or data centers.
Wall-Mounted: Installed directly on walls, saving floor space, ideal for smaller setups or office environments.
2. Size and Weight
Rack-Mounted: Generally larger and heavier, capable of handling more functions and higher power levels.
Wall-Mounted: Smaller and lighter, easier to install and remove.
3. Heat Dissipation
Rack-Mounted: Typically has better heat dissipation designs, suitable for long-term high-load operation.
Wall-Mounted: Relatively weaker heat dissipation, suitable for lower power applications.
4. Application Scenarios
Rack-Mounted: Used in data centers, large industrial equipment, and other high-power, high-performance settings.
Wall-Mounted: Suitable for small businesses, homes, or small equipment power management.
5. Cost
Rack-Mounted: Usually more expensive due to more complex designs and higher power requirements.
Wall-Mounted: Relatively lower cost, suitable for users with budget constraints.
When choosing between the two, consider specific needs, space limitations, and budget constraints.
Pls contact us for more guidence
Application scenarios of AHF :
Industrial Automation: It improves power quality, reduces harmonic distortion, and enhances equipment efficiency, protecting motors and inverters.
Data Centers: In high-density computing environments, APF effectively lowers harmonics, ensuring stable and reliable power supply.
Renewable Energy: In solar and wind energy systems, APF helps optimize power output and improve power quality.
Commercial Buildings: It enhances the power quality of lighting and HVAC systems, reduces energy consumption, and extends equipment lifespan.
Electric Transportation: In EV charging stations, APF minimizes harmonics during the charging process, improving charging efficiency.

Hot Tags: active harmonic filter ahf, China active harmonic filter ahf manufacturers, suppliers, factory, power quality maintenance, electric power quality in substations, electrical harmonic filter, power quality repair, active harmonic filter, power quality filter