0.6 1 1.8 3 kV Indoor Cold Shrink Cable Terminal Tube
✅No Heat Required,Ease and Speed of Installation
✅Excellent Sealing and Moisture Resistance,IP68
✅High Installation Reliability and Quality Consistency
✅Outstanding Environmental Adaptability
✅Easy Maintenance and Wide Applicability
- Product Introduction
0.6 1 1.8 3 kV indoor cold shrink cable terminal tube made from high-quality liquid silicone rubber, the product is available in 3-core, 4-core, and 5-core configurations,Cable Cross-Section Range: 25–400 mm²,primarily designed for low-voltage cable terminations and intermediate connections.
Cold shrinkable cable tube are pre-expanded, rubber-based components used for insulation, sealing, and mechanical protection in cable joints and terminations(dry, low-pollution areas).
● Unlike heat-shrink products, they do not require heating for installation-instead, they rely on elastic memory technology to shrink tightly onto cables when the supporting core is removed.
● Unlike outdoor versions, they prioritize compact design, ease of installation, and cost efficiency while maintaining reliable insulation and sealing.
Model

Key Components & Types
A. Common Products
Cable Terminations (for LV/MV/HV cables)
Straight & Branch Joints (for splicing cables)
Breakout Kits (for transitioning between cable types)
Outdoor/Indoor Terminations (weather-resistant designs)
B. Materials
Silicone Rubber
High-Dielectric Strength Insulation (for electrical reliability)
Stress Control Layer (to manage electric field distribution)
Product Parameters
|
Voltage level |
Product specification |
Product model |
cable cross section (mm²) |
|
|
0.6/1(1.8/3)kV |
3-core Cold Shrink termination Kit |
NLS-3.1 |
25~50 |
|
|
NLS-3.2 |
70~120 |
|||
|
NLS-3.3 |
150~240 |
|||
|
NLS-3.4 |
300~400 |
|||
|
4-Core Cold Shrink terminal Kit |
NLS-4.1 |
25~50 |
||
|
NLS-4.2 |
70~120 |
|||
|
NLS-4.3 |
150~240 |
|||
|
NLS-4.4 |
300~400 |
|||
|
5-core cold Shrink Termination Kit |
NLS-5.1 |
25~50 |
||
|
NLS-5.2 |
70~120 |
|||
|
NLS-5.3 |
150~240 |
|||
|
NLS-5.4 |
300~400 |
|||
Above parameters are typical values,pls contact us for more info
Advantages vs. Heat-Shrink & Other Methods
| Feature | Cold Shrink | Heat Shrink | Taped Joints |
|---|---|---|---|
| Installation | No heat/tools | Requires torch | Manual wrapping |
| Sealing Performance | Excellent | Good | Moderate |
| Weather Resistance | High (silicone) | Moderate (PE) | Low |
| Reusability | No | No | Yes (if undamaged) |
| Speed of Installation | Fast (5–10 min) | Slower (heating) | Slow (skill-dependent) |
Installation Steps (Simplified)
1. Prepare Cable – Strip insulation, clean, and apply semi-conductive tape if needed.
2. Slide Cold Shrink Onto Cable – Ensure correct orientation.
3. Remove Support Core – Pull the spiral core to trigger shrinkage.
4. Secure & Seal – Verify tight fit and use mastic for extra moisture protection.
Applications
● Electrical Panels – Terminations in switchgear, MCCs.
● Data Centers – LV cable joints for server racks.
● Industrial Plants – Motor connections, conveyor systems.
● Commercial Buildings – Risers, distribution boards.

FAQs
Q: Can cold shrink be reused?
A: No-once installed, it cannot be repositioned.
Q: Can indoor cold-shrink be used outdoors?
A: No-lacks UV weather resistance. Use outdoor-rated products.
Q: How long does it last?
A: 20+ years (depending on material and environment).
Q: Is it safer than heat shrink?
A: Yes-no open flame or hot tools required, reducing fire risks
Q: How to verify proper installation?
A: Check for uniform shrinkage and no gaps (use dielectric grease if needed).
Hot Tags: 0.6 1 1.8 3 kV Indoor Cold Shrink Cable Terminal Tube, China 0.6 1 1.8 3 kV Indoor Cold Shrink Cable Terminal Tube manufacturers, suppliers, factory, cold shrinkable cable accessories, cold shrink cable jointing kit, cold shrink splice kit, cold shrinkable termination kit, Cold Shrinkable Intermediate Joint, Cold shrink splices