XGN口-12 Inflatable Ring High Voltage Switchgear
✅Full Insulation,ensure safety
✅Fully Sealed Structure,IP67
✅Intelligent Monitoring System
✅Compact Design,expandable
✅Maintenance-free, long service life (30+ years)
- Product Introduction
Jinneng electric XGN口-12 Inflatable Ring High Voltage Switchgear is a new generation of inflatable ring main unit switchgear which is a composite device encapsulated in a solid metal frame that houses different electrical devices. There are switchgears, the cabinet, circuit breakers, connection cables and other main circuits are sealed inside the gas box filled with insulating gas, the external are main busbar, cable connections, etc.
Model Meaning

①.Gas insulation
②.Rated voltage(kV)
③.G for fixed type,K for expandable,and D for cable branch box configuration
④.Standard module code
⑤.Expansion mode:
LT-left top expansion,RT-right top expansion LS-left side expansion,RS-side expansion
LTRT-left and right top expansion, LTRS-left top expansion right expansion,RTLS-right top left expansion
Technical parameters
| Item | Unit | Load Switch | Combined electric unit | Breaker unit | ||
| Rated voltage | kV | 12/24 | ||||
| Rated frequency | Hz | 50/60 | ||||
| Reted current of main busbar | A | 630,1250 | ||||
| Rated curret | A | 630 | 125 | 630,1250 | ||
| Rated short-circuit breaking current | kA | 31.5 | 20,25/30 | |||
| Rated short circuit making current (peak) | kA | 50 | 80 | 50,63 | ||
| Rated short-time withstand current | Main loop 4s ground loop 4s | kA | 20 | 20,25 | ||
| Ground connection circuit 4s | 17.4 | 17.4,21.7 | ||||
| Rated peak withstand current | Main loop ground loop | kA | 50 | 50,63 | ||
| Ground connection circuit | 43.5 | 43.5/54.6 | ||||
| Rated transfer current | A | 1750(12kV)/1400(24kv) | ||||
| Ability to break and close | E3 level | E2 level | ||||
| Rated insulation level | power frequency withstand voltage | Phase-to-ground/phase-to-phase | kV | 42(12kV)/65(24kV) | ||
| Vacuum gap/isolation gap | 48(12kV)/79(24kV) | |||||
| Lightning impulse withstand voltage (peak) | Phase-to-ground/phase-to-phase | 75(12kV)/125(24kV) | ||||
| Vacuum gap/isolation gap | 85(12kV)/145(24kV) | |||||
| Auxiliary circuit 1min power frequency withstand voltage | kV | 2 | ||||
| Rated single/back-to-back capacitor bank breaking current | A | 400 | ||||
| Rated capacitor banks closing inrush current | kA | 20(50Hz) | ||||
| Mechanical life | Load switch, combination switch | Times | 5000/3000 | 5000/3000 | ||
| Circuit breaker, isolation switch | 10000/3000 | |||||
| SF₆ gas rated pressure (20°C relative value) | Design Level and Rated Filling Level | Mpa | 0.04 | |||
| Minimum functional level | 0.02 | |||||
| Pressure release device operating pressure | 0.14 | |||||
| Protection class | Sealed gas compartment | IP67 | ||||
| Switchgear housing | IP4X | |||||
| Sealing performance | Annual leakage rate≤0.01% | |||||
Note:above parameters are typical value,our company reserves the right of final interpretation.pls contact us
Product Features
● Fully Insulated: All live parts are completely insulated for enhanced safety.
● Fully Sealed: Hermetically sealed design to prevent environmental contamination.
● Gas-Insulated: Uses SF6 or other insulating gases for arc quenching and insulation.
● Ring Main Unit (RMU): Designed for looped power distribution networks.
● High-Voltage: Suitable for medium to high-voltage applications (e.g., 12–40.5 kV).
Usage conditions:
Use Conditions of Gas Insulated Ring Main Unit (GIS RMU):
1.Temperature: -25°C to +40°C.
2. Altitude: ≤ 1000m
3. Humidity and Pollution: Avoid high humidity and heavily polluted environments.
4. Seismic and Wind Loads: good ventilation and no serious vibration and shock.
5. Electrical Parameters: Check to make sure comply with specific voltage, current, and short-circuit current ratings.
6. Safety and Maintenance: comply with safety standards, easy for operation, and safety for maintenance.
7. Installation Requirements: Adequate space for installation and inspection, and ventilation and heat dissipation should be considered.
8.The Ring Main Unit high voltage switchgear should be maintained and inspected regularly to ensure it's under normal operation.
Usage application:
Full sealed and full insulated XGN-12 Insulated Ring Main Unit high voltage switchgear is widely use in following situations:
1.Urban Distribution Networks: GIS is preferred for its small footprint, flexible installation, and high operational reliability
2.Industrial Parks: Industrial parks require stable and reliable power supply, and GIS meets the need for high safety and stability of electrical equipment in these areas.
3.Transportation Hubs: Metro stations, railway stations, airports, and other transportation hubs demand continuous and reliable power supply
4.Wind and Solar Power Stations: In wind and solar power stations, GIS is used to collect and distribute power generated by the turbines or photovoltaic arrays. Its robustness against environmental conditions makes it suitable for outdoor and harsh environments.
5.Military Bases and Government Facilities: In these security-sensitive areas, the high security and sealing of GIS can protect the power system from adverse weather and potential threats.

Hot Tags: xgn口-12 inflatable ring high voltage switchgear, China xgn口-12 inflatable ring high voltage switchgear manufacturers, suppliers, factory, gis switchgear, GIS, Ring main unit, gas switchgear, air cabinet, gas insulated ring main unit