Intelligent Power Factor Compensator

Intelligent Power Factor Compensator

✅Multi-functional and highly integrated ✅Up to 32 devices can be combined freely ✅Self-organizing network and collaborative control ✅Precise and hierarchical compensation ✅Static reactive power compensation for 400V power systems ✅Improve power factor ✅Improve voltage quality ✅Avoid fines

  • Product Introduction
 

 

The Intelligent Power Factor Compensator integrates multiple advanced technologies, including power parameter detection, reactive power compensation control, display, capacitor switching control, intelligent capacitor networking, fault monitoring and protection, and is composed of components such as capacitors and circuit breakers. A single intelligent capacitor can form a complete compensation system, supporting up to 32 intelligent capacitors working together in any combination. The device operates automatically upon startup without the need to set any control parameters, making it simple and flexible to use. It is primarily applied in static reactive power compensation for 400V power systems, effectively improving the grid power factor, reducing line losses, increasing the transformer's output capacity, enhancing voltage quality, and avoiding electricity fines caused by non-compliant power factors.

 

Products Features

 

1. Compact integration and energy saving: Compact structure, all secondary circuits integrated; Low power consumption design, more energy-efficient than traditional ones.
2. Flexible networking and rapid response: Supports up to 32 units in any combination, intelligent networking (fault automatic disconnection/reconnection), power-on completion in the fastest 18 seconds, quick debugging.
3. Advanced switching technology: Zero-crossing switching, no inrush current when turned on (less than 2 times the rated current), no arc when disconnected.
4. Intelligent protection and identification: Multiple protections (overvoltage, undervoltage, undercurrent, phase loss, overharmonic, overtemperature); Automatic identification of current phase symmetry to prevent reverse connection; Delayed switching based on average power factor to reduce the number of actions.
5. Complete human-machine interaction: LCD backlight display of parameters, status and alarms; Supports manual switching.

 

Parameters

 

  • Temperature: ±2°C
  • Voltage: ±0.5%
  • Current: ±1%
  • Power: ±2.5%
  • Power factor: ±0.01%
  • Total power consumption: ≤ 3.5VA
  • Switching surge current: ≤ 2In
  • Dynamic response time: ≤1s
  • Number of networking units: maximum 32 (excluding intelligent capacitor controller)

 

Installation conditions

 

  • Voltage range: Line 400V ± 20%; Phase 230V ± 20%
  • Signal current: AC 0 - 5A
  • Rated frequency: 50Hz ± 2Hz
  • Environmental temperature: -20 to 45°C
  • Distortion environment: Voltage distortion rate ≤ 5%
  • Highest altitude: ≤ 2500 meters
  • Environmental conditions: Surrounding medium has no explosion hazard, no gases that can damage insulation or corrode metals, and no conductive dust.
  • Relative humidity: Air humidity ≤ 90% at 20°C; Higher relative humidity is allowed at lower temperatures.

Note: For these scenarios involving medium frequency furnaces, spot welders, rolling mills, plastic mixers, and medium frequency induction heating equipment, please use with caution. For specific details, please consult our engineers.

 

Installation and debugging

 

1. After the Intelligent Power Factor Compensator is installed and powered on, the CT parameters of the main cabinet must be set (set the transformation ratio value. For example, if the transformer is 2000:5, set it to 400. Only the master device needs to be set). Other parameters can use the factory default values. This is the only parameter that needs to be set for the smart capacitor system. 

 

2. When the capacity of the temporary power supply connected to the capacitor cabinet busbar is less than the capacity of the single largest capacitor, to avoid tripping after capacitor activation, the smart capacitor provides a simulated switching function. After power-up, press and hold the key '' MANU''  and ⬆ simultaneously for 2 seconds, then release. The LCD will simultaneously display the characters "Auto Manual", indicating that this function has been activated. When manually switching on the capacitor at this point, the input LED will light up normally, but the capacitor is not actually engaged.

 

3. Automatic Switching Test: For situations where a simulated current signal cannot be provided, the unit can be shipped as long as the manual switching test functions normally after execution. 

 

Installation size

 

product-8952-4328

Compensation way

Parameter

Rated capacity(kvar)

Outline dimmension L×W×H(mm)

Installation size(mm)

 

Double Cocompensation

(2 circuits)

JN-GE/450-30+30 EP

60

387×83×298

367×45

JN-GE/450-25+25 EP

50

387×83×278

367×45

JN-GE/450-20+20 EP

40

387×83×258

367×45

JN-GE/450-20+15EP

35

387×83×258

367×45

JN-GE/450-15+15EP

30

387×83×238

367×45

JN-GE/450-15+10 EP

25

387×83×238

367×45

JN-GE/450-10+10 EP

20

387×83×238

367×45

JN-GE/450-10+5EP

15

387×83×238

367×45

JN-GE/450-5+5 EP

10

387×83×238

367×45

Seperate compensation

JN-FE/250-30 EP

30

387×83×258

367×45

JN-FE/250-25 EP

25

387×83×258

367×45

JN-FE/250-20 EP

20

387×83×258

367×45

JN-FE/250-15EP

15

387×83×238

367×45

JN-FE/250-10 EP

10

387×83×238

367×45

JN-FE/250-5 EP

5

387×83×238

367×45

 

Order note:

1. The regular Intelligent Power Factor Compensator do not contain detuned reactors, it can't be used in environments with harmonics, please choose the anti-harmonic series inteligent capacitor if used in harmonics environments.
If an intelligent capacitor controller is not configured for the system, an additional current signal adapter needs to be purchased.

 

2. Optional Accesseies

product-1078-317

 

Network cable specifications

 

Serial Number

name

Specification

use

Remark

1

Communication connection cable

8 core

0.3m

Used to connect capacitors mounted on the same layer Between the device and the capacitor

Each capacitor is equipped with one

0.7m

Used to connect capacitors installed on the upper and lower layers. Between the device and the capacitor

Configure according to actual conditions.

1.5m

Used in capacitor self-controlled state, secondary Current transformer connected to capacitor

Each current transformer is equipped with one

3m

Used for connection between controller and capacitor.

Each controller is equipped with one

2

Secondary current mutual inductor

JN-CTI

Current sampling without a controller, used for full Automatic compensation

Without a controller, based on 12 units One product comes with one

JN-CT3

Current sampling without a controller is used for common current sampling. Automatic compensation with mixed subtraction

Without a controller, based on 12 units One product comes with one

 

Current signal adapter model

 

Order Model

Adaptive Compensation Model

Remark

JN-CT1

Joint supplement

This accessory is not needed in applications equipped with intelligent capacitor controllers.

JN-CT3

Total supplementation + separate supplementation (mixed supplementation)

 

Networking Rules

 

1. Once networking is complete, the host is selected based on a priority order: intelligent capacitor controller first, followed by detuned compensation capacitors, and finally standard compensation capacitors.

 

2. Within a single compensation system, one device acts as the host and the rest as secondary units, with a maximum of 32 devices in total.

Automatic networking is triggered every time the system powers on or whenever capacitor parameters are modified. The entire process takes around 18 seconds, and the number of units has little effect on this duration. 

 

4. Automatic and manual addressing modes cannot coexist on the same network-doing so will cause networking errors.

 

5. In automatic addressing mode, each capacitor may be assigned a different address after every networking cycle. This could alter the mapping to the cabinet's indicator lights, but it won't affect the compensation system's normal operation. If a fixed mapping is required, manual addressing can be used instead.

 

When using manual addressing, the host must always be set to address 0. Secondary units must use addresses 1 to 32 in sequence, starting with standard capacitors first, followed by detuned ones. The host must be assigned according to the priority order: controller, detuned capacitor, standard capacitor. For instance, in a system that includes both detuned and standard capacitors, a standard capacitor cannot be set as the host.

 

6.If the host fails and can no longer perform its role, it will automatically drop out of the network and will not participate in re-networking until the fault is resolved. The remaining units will automatically re-network and resume operation after a delay of up to 30 seconds.

 

Advantages and disadvantages of automatic address VS set address

 

 

Advantages

Disadvantages

Automatic address

1. No address setting required

2. No need to understand address setting rules

3. Automatically logs out and automatically re-establishes network in case of host failure.

4. No parameter settings are required when replacing the smart capacitor.

Capacitor cabinet switch indicator lights and intelligent Capacitor number correspondence after each network setup Everything will be different.

Set address

Cabinet switching indicator LEDs and smart capacitors The correspondence between the numbers is fixed.

Users need to be familiar with all controller parameters. The configuration rules ensure that the entire system is repaired in case of a host failure. The compensation system has stopped working.

 

Intelligent capacitor compensation (1-channel compensation) is enabled by default at factory.

Internal parameter number

Parameter name

Host Enable

Sub-machine enable

Remark

0

The capacitance of the first group of capacitors

     

1

The capacitance of the second group of capacitors

     

2

Investment threshold

 

●

 

3

Throwing delay

     

4

CT ratio

     

5

Network address

O①

 

When the host is Au

6

Temperature threshold

     

7

Common overvoltage compensation

     

8

Total two-stage overvoltage compensation

     

9

Jointly compensate for undervoltage

     

10

First-level overvoltage compensation

     

11

Secondary overvoltage compensation

●

●

 

12

Make up for the lack of pressure

●

●

 

13

Voltage harmonic threshold

 

●

 

14

Protection delay

 

●

 

15

Main counter undercurrent threshold

●

●

 

16

Capacitor discharge delay

●

●

 

17

Voltage imbalance threshold

●

●

 

18

Removal threshold

●

●

 

 

The common-compensation smart capacitor is enabled by default at the factory.

Internal parameter number

Parameter name

Host Enable

Sub-machine enable

Remark

0

The capacitance of the first group of capacitors

     

1

The capacitance of the second group of capacitors

     

2

Investment threshold

●

●

 

3

Throwing delay

●

●

 

4

CT ratio

●

●

 

5

Network address

O①

●

When the host is Au

6

Temperature threshold

●

●

 

7

Common overvoltage compensation

     

8

Total two-stage overvoltage compensation

●

 

For the intelligent capacitance measurement and control instrument Alternatively, the threshold parameter of the smart capacitor can be multiplied by 1.732 and then overwritten.

9

Jointly compensate for undervoltage

●

●

10

First-level overvoltage compensation

   

11

Secondary overvoltage compensation

   

12

Make up for the lack of pressure

 

●

13

Voltage harmonic threshold

●

●

 

14

Protection delay

●

●

 

15

Main counter undercurrent threshold

●

●

 

16

Capacitor discharge delay

●

●

 

17

Voltage imbalance threshold

●

●

 

18

Removal threshold

●

●

 

 

①: When the address code of the host is in the automatic address mode, after the network is completed or the controller is modified, the host will broadcast a message to change the address codes of all the slave machines to the automatic address mode. 

②: When the user needs to change the address mode to the automatic mode, they only need to modify the host to complete the operation. 

 

Note: The host enable indicates that the intelligent capacitor is in the host mode and it covers all the parameter items for all the slave capacitors.
The slave enable indicates that the intelligent capacitor is in the slave mode and its parameters are being overridden.  

 

Hot Tags: intelligent power factor compensator, China intelligent power factor compensator manufacturers, suppliers, factory, capacitor for transportation, Integrated Power Smart Capacitor Compensation, reactive power compensation capacitor, fixed capacitor, capacitor for assembly line, capacitor with different mounting styles