2026-4-02Differences and Applications of Four Types of Low-Voltage Switchgear: GGD, GC...
Low-voltage switchgear is a piece of equipment used for power distribution and control in power systems, playing a vital role in power systems. Such switchgear is generally applied in low-voltage powe -

2026-3-31Application Scenarios, Configuration Modes and Precautions of Box-type Substa...
Application Scenarios, Configuration Modes and Precautions of Box-type Substation A box-type substation is a factory prefabricated indoor and outdoor compact power distribution equipment, which integr -

2026-3-27Application of Lightning Arresters and Surge Protective Devices
Although both lightning arresters and surge protective devices (SPDs) can protect electrical equipment, they differ significantly in performance and application principles. Lightning arresters mainly -

2026-3-23System Harmonic Pollution and Total Harmonic Distortion
"Your power distribution system suffers from severe harmonic pollution. The harmonic distortion rate is as high as over 30% and requires treatment!""The harmonics are excessive and pose a serious thre -

2026-3-25Comparison of the Advantages and Disadvantages of External Discharge Resistor...
✅ Advantages - Better heat dissipation - Flexible and adjustable - Easy fault diagnosis - Low maintenance cost - Flexible layout ❌ Disadvantages - Higher cost - More installation steps - Re -

2026-3-19Selection and Setting Points of Circuit Breakers
The selection of circuit breakers shall be based on actual operating conditions, including utilization category, rated operational voltage, rated current, rated setting current of the release, and oth -

2026-3-17Summary of Calculation Formulas for Heating of Electrical Equipment
I. Heating Capacity of High and Low Voltage Switchgear / Panels The heat dissipation of high-voltage switchgear panels can be calculated using the following formula: I g : Operating current of the hi -

2026-3-13Fault Analysis and Countermeasures of Switchgear
What is Switchgear? Switchgear is an assembly composed of one or more low-voltage switching devices and associated control, measurement, signaling, protection, regulation and other equipment.All inter -

2026-3-10kVA ≠ kW: A Power Concept Misunderstood by 90% of People
There is an 1000 kVA transformer with an existing load of approximately 200 kW. If we want to add about 600 kW of new load, can this transformer withstand it? This question involves two units: kVA and -

2026-3-07Jinneng indoor dry type power factor correction capacitor pass 6kV terminal t...
According to the IEC60831-1 standard, the terminal to case withstand voltage test voltage for indoor power factor correction capacitors is 3kV. Jinneng Electric Company conducted random tests on 10 mo -

2026-3-02How to Select the Capacity of Reactive Power Compensation Cabinets
In power systems, the configured capacity of reactive power compensation cabinets directly affects the improvement effect of power quality and the stability of equipment operation. To correctly select -

2026-2-28When should power capacitors be replaced based on capacity degradation?
What are the recommended and mandatory thresholds? Regarding the extent to which power capacitor capacity degradation necessitates replacement, there are different reference standards within the indus