AKSG Variable Frequency Output Electrical Reactance
✅ Limits dv/dt– Protects motor insulation from fast-rising PWM pulses.
✅ Reduces Harmonic Distortion – Smooths current waveform, minimizing motor heating.
✅ Suppresses Voltage Overshoot – Prevents reflected wave issues in long cable runs.
✅ Improves EMI Performance – Reduces high-frequency noise radiation.
✅ Class H (180°C) Insulation
- Product Introduction
Jinneng electric AKSG Variable Frequency Output Electrical Reactor, also known as a motor reactor, inverter output reactor, or dv/dt reactor, is an inductive component connected in series between the output of a frequency converter (or inverter) and the motor. It is a crucial auxiliary device in modern AC drive systems.
The primary functions are to improve the output waveform, protect the motor and equipment, and suppress electromagnetic interference.
Model and meaning:

● AK: AK is alternative current reactor.
● S: S is number of phases, here is three-phase 380V 50HZ reactor.
● G: G is dry self-cooling
● 10A is mean the rated current of the reactor, the capacity range is 5A~1100A
● AKSG series reactor is for the inlet end of the inverter named input reactor, commonly known as the inlet reactor.
● AKSG reactor is divided into copper input reactor and aluminum output reactor.
● AKSG reactor winding method is to wind the input reactor and wind the output reactor respectively.
● AKSG reactor can be divided into conventional reactor and non-standard reactor.
Usage introduction
1.Rated voltage :AC110V~1140V(conventional voltage 380V, special need to be customized)
2.Rated frequency :50HZ/60HZ
3.Rated voltage drop :1%-14%(conventional reactance input 2% output 4%, current limiting action 1%/6%/7%,
suppression of 5,7 11 harmonics, 12%14% suppression of more than 3 harmonics)
4.Working voltage: core winding 3000VAC/50HZ/5MA/60S no fly arc, no breakdown (factory test humidity <55%)
5.Insulation resistance: core winding 1000VDC≥100MM;
6.Working temperature rise:

7.Working noise :≤60dB(test 1M away from the reactor level);
|
Frequency converter |
Model |
Material |
Mounting |
Dimension |
Model |
Material |
Mounting |
Dimension |
|
0.75 |
AKSG-10A |
aluminum |
75*55 |
140*75*145 |
AKSG-10A |
Copper |
75*55 |
140*75*145 |
|
1.5 |
||||||||
|
2.5 |
||||||||
|
4 |
AKSG-15A |
AKSG-15A |
||||||
|
5.5 |
||||||||
|
7.5 |
AKSG-20A |
80*70 |
170*150*135 |
AKSG-20A |
||||
|
11 |
AKSG-30A |
AKSG-30A |
80*70 |
170*150*135 |
||||
|
15 |
AKSG-40A |
AKSG-40A |
||||||
|
18 |
AKSG-50A |
110*65 |
210*155*167 |
AKSG-50A |
||||
|
22 |
AKSG-60A |
AKSG-60A |
||||||
|
30 |
AKSG-80A |
110*82 |
210*180*167 |
AKSG-80A |
110*62 |
210*155*167 |
||
|
37 |
AKSG-110A |
AKSG-90A |
110*82 |
210*180*167 |
||||
|
45 |
AKSG-125A |
AKSG-125A |
||||||
|
55 |
AKSG-150A |
130*110 |
240*215*210 |
AKSG-150A |
||||
|
75 |
AKSG-200A |
AKSG-200A |
130*110 |
240*215*210 |
||||
|
93 |
AKSG-250A |
240*215*260 |
AKSG-250A |
130*110 |
240*215*260 |
|||
|
110 |
AKSG-275A |
AKSG-275A |
||||||
|
132 |
AKSG-330A |
170*118 |
280*240*230 |
AKSG-360A |
||||
|
160 |
AKSG-450A |
193*140 |
320*260*290 |
AKSG-450A |
170*118 |
280*240*280 |
||
|
187 |
AKSG-500A |
193*140 |
320*260*340 |
AKSG-500A |
||||
|
200 |
AKSG-510A |
AKSG-510A |
||||||
|
220 |
AKSG-540A |
AKSG-540A |
193*120 |
320*240*290 |
||||
|
250 |
AKSG-625A |
AKSG-625A |
||||||
|
315 |
AKSG-800A |
246*170 |
376*290*360 |
AKSG-800A |
193*140 |
320*260*290 |
||
|
375 |
AKSG-1000A |
376*290*410 |
AKSG-1000A |
|||||
|
400 |
AKSG-1100A |
AKSG-1100A |
320*260*340 |
Performance
1 The core column is divided into uniform small pieces through multiple air gaps. The air gap adopts high temperature and high strength bonding adhesive to closely bond each small section of the core column with the upper and lower iron yoke.
2 the foil adopts F&H class insulation level. The reliability of long-term operation is greatly improved.
3 the reactor take vacuum pressure dipping process (vpi), which can reduce reactor noise and vibration during operation. Our product have high mechanical strength and long lifespan
4 low temperature rise, small loss. High utilization rate of integrated platform. Easy to install.
Difference from Input Reactor
| Feature | Output Reactor | Input Reactor (AC Line Reactor) |
|---|---|---|
| Installation Location | Between the inverter output (U/V/W) and the motor | Between the mains power supply and the inverter input (R/S/T) |
| Primary Function | Protects the motor, suppresses dv/dt, reduces the impact of harmonics on the motor. | Protects the inverter, suppresses grid harmonics, improves input power factor, absorbs line-side surges. |
| Addresses Issues | Reflected voltage, motor insulation, motor heating, long cables. | Grid harmonic pollution, voltage imbalance, power supply transients. |
Process Flow

Certification:
New patent certificate/Design patent certificate, business license, expert workstation, production license, high-tech enterprise certificate, CE certificate, CCC certificate, SGS certificate, quality inspection report,and ISO9001,ISO14001,OHS18001, and other certifications.

Hot Tags: aksg variable frequency output electrical reactance, China aksg variable frequency output electrical reactance manufacturers, suppliers, factory, power factor reactor, reactor for condensation, CKSG, electric reactor, reactor for cutting, reactance
You Might Also Like