SCB Epoxy Resin Dry Type Transformer
Vacuum Pressure Casting (VPC): High-voltage and low-voltage coils are wound with copper/aluminum and then impregnated under high vacuum. This removes all air pockets, forming a solid, crack-resistant insulation body.
Superior Thermal Performance: Designed with Class F insulation (155°C) and available with AN/AF cooling modes (Air Natural or Air Forced), ensuring stable operation even under heavy loads.
Flexible Configuration: Available in 30-2500kVA capacities, 10kV/35kV voltage classes, and various connection groups (Yyn0, Dyn11) to match your specific grid requirements.
Harsh Environment Ready: With protection ratings up to IP23, these transformers can withstand dusty workshops, coastal areas, and fluctuating industrial loads.
Global Compliance: Manufactured to meet both Chinese GB standards and international IEC 60076 standards, ensuring seamless integration into global projects.
- Product Introduction
Core Structure & Manufacturing Process
Advanced Vacuum Casting Technology (Coils):
Both high-voltage and low-voltage coils are wound from premium copper or aluminum conductors. During manufacturing, liquid epoxy resin is injected under high-vacuum conditions. This critical process completely extracts trapped air and moisture, ensuring the resin fully penetrates every gap. The result is a void-free, fully sealed, and rigid insulation body that offers exceptional resistance to short-circuit forces and prevents partial discharge.High-Efficiency Magnetic Core:
The core is constructed from high-grade cold-rolled silicon steel sheets using a stepped stacking process. This precise manufacturing significantly minimizes hysteresis and eddy current losses, delivering superior energy efficiency and ultra-low noise levels during operation.- Flexible & Reliable Cooling System:
Designed without insulating oil, the transformer relies on highly efficient air cooling. It operates in Air Natural (AN) mode for continuous standard load, and seamlessly switches to Air Forced (AF) mode when needed, allowing for temporary overload capacity to handle peak power demands safely.
Technical Parameters
Table 1: General Technical Specifications
| Technical Parameter | Value / Unit |
|---|---|
| Design Standards | IEC 60076, GB/T 1094, GB/T 1094.11, DIN 42523 |
| Capacity Range | 30 - 2500 kVA |
| Voltage Level | 10 kV, 20 kV, 35 kV |
| Rated Frequency | 50 Hz |
| Phase Number | Three-phase or Single-phase |
| Connection Group | Yyn0, Dyn11 (Customizable) |
| Tap Changer Mode | No-Load Tap Changer (NLTC) / On-Load Tap Changer (OLTC) |
| Tap Range | ±5%, ±2×2.5%, ±4×2.5% |
| Insulation Class | Class F (155°C) |
| Max. Temperature Rise | 100 K |
| Cooling Method | Air Natural (AN) / Air Forced (AF) |
| Protection Class | IP00, IP20, IP23 |
Table 2: Dielectric Strength & Insulation Levels (Critical)
| Voltage Level | Power Freq. Withstand Voltage (1min) | Lightning Impulse Withstand Voltage |
|---|---|---|
| 10 kV | 35 kV | 75 kV |
| 20 kV | 50 kV | 125 kV |
| 35 kV | 70 kV | 170 kV |
Table: Transformer Technology Comparison: Why Choose Epoxy Resin Cast?
| Key Characteristics | Epoxy Resin Cast (Our Product) | Open-Ventilated Dry-Type | Oil-Immersed |
|---|---|---|---|
| Insulating Medium | Solid Epoxy Resin (Vacuum Cast) | Air, Gas, or Impregnated Varnish | Mineral Oil or Synthetic Ester |
| Protection Level | High (IP00 - IP23) | Low (Requires External Enclosure) | Medium (Sealed Tank) |
| Fire Performance | Excellent (Self-Extinguishing) | Good (But Coils are Exposed) | Poor (Combustible Oil) |
| Environmental Adaptability | Exceptional (Moisture & Dust Resistant) | Poor (Susceptible to Fouling) | Good (But Oil Ages Over Time) |
| Maintenance Requirements | Virtually Maintenance-Free | Requires Periodic Cleaning | Needs Regular Oil Testing & Monitoring |
Application Scenarios

● Indoor Power Distribution: High-rise office buildings, commercial centers, hospitals, schools, stadiums.
● Transportation Infrastructure: Subways, light rail, train stations, airports, tunnels.
● Industrial and Mining Enterprises: Chemical plants, shipyards, mines, and other sites with harsh environments and fluctuating loads.
● New Energy: Package substations for photovoltaic power stations and wind farms.
FAQ
Q1: Can SCB epoxy resin transformers be installed outdoors?
A: Yes. While dry-type transformers are typically designed for indoor use, our SCB series can be equipped with an IP23 protective enclosure. This enclosure prevents the ingress of water droplets at a 60° angle and solid foreign objects, making it safe for outdoor installation in harsh environments.
Q2: What is the expected lifespan of an epoxy resin cast transformer?
A: Thanks to the advanced vacuum casting process, the coils form a rigid, void-free solid insulation body. This makes the transformer highly resistant to short-circuit forces, moisture, and thermal aging. Under normal operating conditions, it boasts a long service life of over 30 years with virtually zero maintenance.
Q3: How does the Air Forced (AF) cooling mode work?
A: In standard Air Natural (AN) mode, the transformer operates at its rated capacity. However, if the load increases, the integrated low-noise fans can be automatically activated to enter Air Forced (AF) mode. This enhances heat dissipation and allows the transformer to safely handle an overload capacity of up to 40-50% above its rated value.
Q4: Is this transformer suitable for high-humidity or corrosive environments?
A: Absolutely. The high-voltage and low-voltage coils are completely encapsulated under high vacuum. This fully sealed structure prevents moisture, dust, salt fog, and corrosive gases from penetrating the insulation, ensuring reliable operation even in 100% humidity or severe industrial conditions.
Q5: What safety features are integrated into the SCB series?
A: Safety is our top priority. The epoxy resin used is flame-retardant and self-extinguishing, completely eliminating fire and explosion risks. Additionally, we integrate a smart temperature control system with PT100 sensors that automatically triggers alarms and trips the circuit breaker in case of overheating.
Hot Tags: scb epoxy resin dry type transformer, China scb epoxy resin dry type transformer manufacturers, suppliers, factory, assembled inductors with high inductance, oil-immersed transformer, assembled electric equipment, European Outdoor Electrical Transformer Substation, vibration free transformer, dry cast resin transformers